Nanosecond
Q-Switched Nd:YAG Laser System
$34,800
Via-AeonEx price
Included in the price: Protect 36+ (36 months of coverage), scheduled preventive maintenance, practice marketing support and expert device selection support.
The Q-Switched Nd:YAG is FDA Cleared (K252515).
Overview
Offer dark-ink tattoo removal, pigment treatment, hair reduction and resurfacing from one nanosecond platform, at a little over half the Via-AeonEx price of a picosecond system. Protect 36+ included.
A Q-switched Nd:YAG laser producing 5 to 6 nanosecond (ns, one billionth of a second) pulses at up to 800 mJ, with 1064 nm, 532 nm and a long-pulse mode, a 2 to 10 mm spot and 1 to 10 Hz. FDA clearance covers the 1064 nm wavelength only.
Wavelengths
2 (1064, 532 nm)
Power
133 to 160 MW peak
Spot size
2 to 10 mm
Protection
Protect 36+ included
Reviewed by Jan Pretorius, CEO · Last updated November 2026

Device Features
5 to 6 ns pulses: the standard Q-switched range of 5 to 10 ns that most tattoo removal protocols were built on.
Four cleared uses at 1064 nm: dark-ink tattoos, benign pigmented lesions, hair reduction and resurfacing for acne scars and wrinkles, so the device earns beyond tattoos.
Lower capital cost: about 55 to 62% of the Via AeonEx PicoIris price, often the better business choice for lower-volume clinics.
800 mJ maximum pulse energy: paired with the 10 mm spot, it carries energy deeper on dense dark ink.
Air plus water cooling: supports consistent output across back-to-back sessions.
15.6 inch touchscreen: clear parameter control during treatment.
Predictable running cost: the lamp rod is rated for about 3 million shots before replacement.

Specifications & Comparison
Q-Switched Nd:YAG specifications | Compare to other Q-switched lasers | How it compares |
|---|---|---|
Device Name: Q-Switched Nd:YAG Laser 1064 nm/532 nm | NA | Same technology |
FDA Status: FDA Cleared K252515 (1064 nm only) | NA | |
Classification: Class II medical device | NA | NA |
Product Technology: Q-switched Nd:YAG aesthetic laser (nanosecond) | Q-switched laser | Same technology |
Wavelengths: 1064 nm, 532 nm and long-pulse mode | Devices offer one to four wavelengths. Most include 532 nm and 1064 nm as standard. Optional or less common wavelengths include: 585 nm (dye); 650 nm (dye); 694 nm (ruby); 755 nm (alexandrite); 1320 nm | Standard device wavelengths |
Pulse Width: 5 to 6 ns | 2 ns – 0.5 ms | Top-tier device specifications |
Peak Power: About 133 to 160 MW | 30 – 350 MW | Mid-tier power |
Maximum Pulse Energy: 800 mJ | Fluence 0.9 – 500 J/cm² | Top-tier device |
Repetition Rate: 1 to 10 Hz | 0.5 – 25 Hz; most up to 10 Hz | Like most peers |
Spot Size: 2 to 10 mm | 1 – 16 mm; fractional tips 3×3 – 6×6 mm | Similar range to peers |
Fractional Delivery: No | Some devices offer fractional tips (3×3 – 6×6 mm) | No fractional option |
Cooling Type: Air and water | Air cooling / water cooling / air plus water cooling / contact cooling / external cooling only | Mid-tier cooling |
Consumables: Lamp rod | Varies per device | NA |
Estimated Replacement Interval: About 3 million shots | Most Q-switched device handpieces are 500k to 2,000k shots | Top-tier device |
Indications: As cleared at 1064 nm (see Clinical Indications) | Tattoo removal (multicolor inks); benign pigmented lesions; nevus of Ota; melasma; vascular lesions; skin toning and rejuvenation; carbon peel; dermatologic and surgical uses | Standard device |
Graphic User Interface: 15.6 inch TFT color touchscreen | Varies from LCD screens to modern GUIs and sizes from 5'-'15 | Top-tier device interface |
Device Dimensions: | Every device is different. Most are about 30–55 cm wide, 80–105 cm deep and 85–105 cm tall (all estimates). | NA |
Device Weight: 90 kg (198 lbs) | 60 – 150 kg | Middle of the weight range |
Indications are as cleared by the FDA and are provided for product identification. Feature and specification information is based on manufacturer data and published sources; individual results may vary. AeonEx does not make independent clinical or medical claims for this product.
Compare
Q-Switched Nd:YAG
with
Alternatives in the same category, with the main difference at a glance.
Who This Device Is For
MedSpas and dermatology practices adding tattoo removal on a controlled capital budget.
Lower to moderate tattoo volume, where a picosecond premium takes longer to recover.
Practices treating dark-ink tattoos (black, blue, brown) and benign dermal pigmented lesions such as Nevus of Ota, common nevi and melasma.
Clinics that also want 1064 nm hair reduction and acne scar and wrinkle resurfacing from the same device.
Clinical Indications
Removal of dark ink (black, blue and brown) tattoos
Removal of benign dermal pigmented lesions, including Nevus of Ota, common nevi and melasma
Removal or lightening of unwanted hair, with or without adjuvant preparation
Skin resurfacing procedures for acne scars and wrinkles
Cost of Ownership
What the Via-AeonEx price includes
OEM warranty
AeonEx Protect 36+ (36 months device coverage plus a loaner if you’re ever down)
Shipping
Virtual training
Taxes and tariffs (where applicable)
Practice sales support package
U.S.-based technical support
Device accessories
Consumables
Consumable | Typical replacement interval | Approx. cost per treatment |
|---|---|---|
Lamp rod | About 3 million shots | Not Indicated |
Other purchase considerations
Device and equipment financing is available
Onsite device installation is available
Contact us to request a no-cost device expert Zoom
System Description
The Q-Switched Nd:YAG is a nanosecond laser system for practices that want proven tattoo and pigment technology at a lower capital cost. It produces 5 to 6 ns pulses with up to 800 mJ of energy and an approximate 133 to 160 MW of peak power, through a 2 to 10 mm spot at 1 to 10 Hz.
Its FDA clearance, K252515, covers the 1064 nm wavelength for dark-ink tattoos, benign dermal pigmented lesions including Nevus of Ota, common nevi and melasma, removal or lightening of unwanted hair, and resurfacing for acne scars and wrinkles. The 532 nm wavelength and long-pulse mode are on the device but outside that clearance.
Clinics comparing Q-Switched Nd:YAG vs PicoSure should weigh throughput against capital: picosecond systems tend to clear ink in fewer sessions, while a Q-switched laser costs far less to own. To compare FDA-cleared Q-switched Nd:YAG lasers for clinics, use the specifications table, which sets each figure against the US competitor range. The Via AeonEx price of $34,800 includes Protect 36+ coverage, training and shipping, and the lamp rod is rated for about 3 million shots. Use this price and specs comparison to decide whether it is the best Q-switched laser for tattoo removal clinics at your volume.
FAQ
How much does the Q-Switched Nd:YAG cost?
The Via AeonEx price is $34,800. It includes Protect 36+ coverage, scheduled preventive maintenance, the practice marketing support package and expert device selection support, plus the OEM warranty, shipping, virtual training, taxes and tariffs where applicable, device accessories and U.S. technical support.
Is the Q-Switched Nd:YAG FDA cleared?
Yes, at 1064 nm. 510(k) K252515 covers dark-ink tattoos, benign dermal pigmented lesions, hair removal or lightening, and resurfacing for acne scars and wrinkles. The 532 nm wavelength and long-pulse mode are not part of that clearance.
Q-switched vs picosecond: what’s the difference?
Q-switched lasers fire nanosecond pulses of about 5 to 10 ns; picosecond lasers fire pulses roughly a thousand times shorter. Picosecond systems tend to need fewer tattoo sessions, while Q-switched systems cost less to buy.
What consumables does the Q-Switched Nd:YAG need?
The main consumable is the lamp rod, rated for about 3 million shots. Budget separately for wavelength-matched eye protection.
Can it be used for hair reduction?
Yes. The 1064 nm clearance includes removal or lightening of unwanted hair, with or without adjuvant preparation.
Regulatory Notice
Professional Regulatory Notice & Restricted Device Statement: This device is a professional-grade system. Per 21 CFR 801.109, sale is restricted to licensed healthcare practitioners or authorized clinical facilities. Licensure verification is mandatory prior to order fulfillment.
Reviewed by Jan Pretorius, CEO · Last updated November 2026
Ready to learn more?
Email: info@aesthetics-exchange.com | Phone: +1.917.881.9501
Nanosecond
Q-Switched Nd:YAG Laser System
$34,800
Via-AeonEx price
Included in the price: Protect 36+ (36 months of coverage), scheduled preventive maintenance, practice marketing support and expert device selection support.
The Q-Switched Nd:YAG is FDA Cleared (K252515).
Overview
Offer dark-ink tattoo removal, pigment treatment, hair reduction and resurfacing from one nanosecond platform, at a little over half the Via-AeonEx price of a picosecond system. Protect 36+ included.
A Q-switched Nd:YAG laser producing 5 to 6 nanosecond (ns, one billionth of a second) pulses at up to 800 mJ, with 1064 nm, 532 nm and a long-pulse mode, a 2 to 10 mm spot and 1 to 10 Hz. FDA clearance covers the 1064 nm wavelength only.
Wavelengths
2 (1064, 532 nm)
Power
133 to 160 MW peak
Spot size
2 to 10 mm
Protection
Protect 36+ included
Reviewed by Jan Pretorius, CEO · Last updated November 2026

Device Features
5 to 6 ns pulses: the standard Q-switched range of 5 to 10 ns that most tattoo removal protocols were built on.
Four cleared uses at 1064 nm: dark-ink tattoos, benign pigmented lesions, hair reduction and resurfacing for acne scars and wrinkles, so the device earns beyond tattoos.
Lower capital cost: about 55 to 62% of the Via AeonEx PicoIris price, often the better business choice for lower-volume clinics.
800 mJ maximum pulse energy: paired with the 10 mm spot, it carries energy deeper on dense dark ink.
Air plus water cooling: supports consistent output across back-to-back sessions.
15.6 inch touchscreen: clear parameter control during treatment.
Predictable running cost: the lamp rod is rated for about 3 million shots before replacement.

Specifications & Comparison
Q-Switched Nd:YAG specifications | Compare to other Q-switched lasers | How it compares |
|---|---|---|
Device Name: Q-Switched Nd:YAG Laser 1064 nm/532 nm | NA | Same technology |
FDA Status: FDA Cleared K252515 (1064 nm only) | NA | |
Classification: Class II medical device | NA | NA |
Product Technology: Q-switched Nd:YAG aesthetic laser (nanosecond) | Q-switched laser | Same technology |
Wavelengths: 1064 nm, 532 nm and long-pulse mode | Devices offer one to four wavelengths. Most include 532 nm and 1064 nm as standard. Optional or less common wavelengths include: 585 nm (dye); 650 nm (dye); 694 nm (ruby); 755 nm (alexandrite); 1320 nm | Standard device wavelengths |
Pulse Width: 5 to 6 ns | 2 ns – 0.5 ms | Top-tier device specifications |
Peak Power: About 133 to 160 MW | 30 – 350 MW | Mid-tier power |
Maximum Pulse Energy: 800 mJ | Fluence 0.9 – 500 J/cm² | Top-tier device |
Repetition Rate: 1 to 10 Hz | 0.5 – 25 Hz; most up to 10 Hz | Like most peers |
Spot Size: 2 to 10 mm | 1 – 16 mm; fractional tips 3×3 – 6×6 mm | Similar range to peers |
Fractional Delivery: No | Some devices offer fractional tips (3×3 – 6×6 mm) | No fractional option |
Cooling Type: Air and water | Air cooling / water cooling / air plus water cooling / contact cooling / external cooling only | Mid-tier cooling |
Consumables: Lamp rod | Varies per device | NA |
Estimated Replacement Interval: About 3 million shots | Most Q-switched device handpieces are 500k to 2,000k shots | Top-tier device |
Indications: As cleared at 1064 nm (see Clinical Indications) | Tattoo removal (multicolor inks); benign pigmented lesions; nevus of Ota; melasma; vascular lesions; skin toning and rejuvenation; carbon peel; dermatologic and surgical uses | Standard device |
Graphic User Interface: 15.6 inch TFT color touchscreen | Varies from LCD screens to modern GUIs and sizes from 5'-'15 | Top-tier device interface |
Device Dimensions: | Every device is different. Most are about 30–55 cm wide, 80–105 cm deep and 85–105 cm tall (all estimates). | NA |
Device Weight: 90 kg (198 lbs) | 60 – 150 kg | Middle of the weight range |
Indications are as cleared by the FDA and are provided for product identification. Feature and specification information is based on manufacturer data and published sources; individual results may vary. AeonEx does not make independent clinical or medical claims for this product.
Compare
Q-Switched Nd:YAG
with
Alternatives in the same category, with the main difference at a glance.
Who This Device Is For
MedSpas and dermatology practices adding tattoo removal on a controlled capital budget.
Lower to moderate tattoo volume, where a picosecond premium takes longer to recover.
Practices treating dark-ink tattoos (black, blue, brown) and benign dermal pigmented lesions such as Nevus of Ota, common nevi and melasma.
Clinics that also want 1064 nm hair reduction and acne scar and wrinkle resurfacing from the same device.
Clinical Indications
Removal of dark ink (black, blue and brown) tattoos
Removal of benign dermal pigmented lesions, including Nevus of Ota, common nevi and melasma
Removal or lightening of unwanted hair, with or without adjuvant preparation
Skin resurfacing procedures for acne scars and wrinkles
Cost of Ownership
What the Via-AeonEx price includes
OEM warranty
AeonEx Protect 36+ (36 months device coverage plus a loaner if you’re ever down)
Shipping
Virtual training
Taxes and tariffs (where applicable)
Practice sales support package
U.S.-based technical support
Device accessories
Consumables
Consumable | Typical replacement interval | Approx. cost per treatment |
|---|---|---|
Lamp rod | About 3 million shots | Not Indicated |
Other purchase considerations
Device and equipment financing is available
Onsite device installation is available
Contact us to request a no-cost device expert Zoom
System Description
The Q-Switched Nd:YAG is a nanosecond laser system for practices that want proven tattoo and pigment technology at a lower capital cost. It produces 5 to 6 ns pulses with up to 800 mJ of energy and an approximate 133 to 160 MW of peak power, through a 2 to 10 mm spot at 1 to 10 Hz.
Its FDA clearance, K252515, covers the 1064 nm wavelength for dark-ink tattoos, benign dermal pigmented lesions including Nevus of Ota, common nevi and melasma, removal or lightening of unwanted hair, and resurfacing for acne scars and wrinkles. The 532 nm wavelength and long-pulse mode are on the device but outside that clearance.
Clinics comparing Q-Switched Nd:YAG vs PicoSure should weigh throughput against capital: picosecond systems tend to clear ink in fewer sessions, while a Q-switched laser costs far less to own. To compare FDA-cleared Q-switched Nd:YAG lasers for clinics, use the specifications table, which sets each figure against the US competitor range. The Via AeonEx price of $34,800 includes Protect 36+ coverage, training and shipping, and the lamp rod is rated for about 3 million shots. Use this price and specs comparison to decide whether it is the best Q-switched laser for tattoo removal clinics at your volume.
FAQ
How much does the Q-Switched Nd:YAG cost?
The Via AeonEx price is $34,800. It includes Protect 36+ coverage, scheduled preventive maintenance, the practice marketing support package and expert device selection support, plus the OEM warranty, shipping, virtual training, taxes and tariffs where applicable, device accessories and U.S. technical support.
Is the Q-Switched Nd:YAG FDA cleared?
Yes, at 1064 nm. 510(k) K252515 covers dark-ink tattoos, benign dermal pigmented lesions, hair removal or lightening, and resurfacing for acne scars and wrinkles. The 532 nm wavelength and long-pulse mode are not part of that clearance.
Q-switched vs picosecond: what’s the difference?
Q-switched lasers fire nanosecond pulses of about 5 to 10 ns; picosecond lasers fire pulses roughly a thousand times shorter. Picosecond systems tend to need fewer tattoo sessions, while Q-switched systems cost less to buy.
What consumables does the Q-Switched Nd:YAG need?
The main consumable is the lamp rod, rated for about 3 million shots. Budget separately for wavelength-matched eye protection.
Can it be used for hair reduction?
Yes. The 1064 nm clearance includes removal or lightening of unwanted hair, with or without adjuvant preparation.
Regulatory Notice
Professional Regulatory Notice & Restricted Device Statement: This device is a professional-grade system. Per 21 CFR 801.109, sale is restricted to licensed healthcare practitioners or authorized clinical facilities. Licensure verification is mandatory prior to order fulfillment.
Reviewed by Jan Pretorius, CEO · Last updated November 2026
Ready to learn more?
Email: info@aesthetics-exchange.com | Phone: +1.917.881.9501
